A camera on a food line takes foaming detergent, disinfectant and high-pressure hot water at the end of every shift. An office camera carries this load for a few months; then its dome turns cloudy, its gasket swells and water gets in. There’s worse: the camera itself can become a source of foreign matter. The criteria below let quality, production and IT teams choose the housing, protection class, material and mounting detail suited to the hygiene zone at the same table.
What are cameras installed for in a food facility?
In food factories, enterprise camera systems don’t have a single purpose. Each purpose needs a different image level, so scenarios are written before choosing products:
- Security and access: Production area entrances, hygiene barriers (boot washing, hand disinfection points) and raw material receiving doors.
- Food defense: Deterring unauthorized tampering in areas with exposed product and reviewing incidents afterwards. The food defense requirements of standards such as FSSC 22000, BRCGS and IFS may call for these controls depending on the risk assessment.
- Quality and traceability: On filling, packaging, labeling and weighing lines, visual evidence for the question “under what conditions was that batch produced” when a complaint or recall arrives.
- Occupational safety: Forklift–pedestrian crossings and machine surroundings; general design principles are covered separately in the factory camera system design guide.
The subject here is narrow and concrete: how does the camera serving these purposes survive hygiene and washdown conditions?
IP69K and washdown resistance: what does each test prove?
The second digit of the IP code is protection against water, and each digit is a separate test scenario. A sentence you often hear is “IP68, there’s nothing higher, it survives washdown too.” It’s wrong. IP68 tests long-term immersion; IP69K tests a high-pressure, hot water jet from close range. A washdown zone needs the latter.
| Class | Condition tested | Meaning in a food area |
|---|---|---|
| IP66 | Powerful water jet (high flow, low pressure) | Hose rinsing; insufficient for high-pressure washdown |
| IP67 | Temporary immersion | Puddles and splashing; not a jet test |
| IP68 | Continuous immersion under the conditions stated by the manufacturer | Doesn’t prove washdown resistance on its own |
| IP69K | High-pressure, high-temperature water jet from close range | Target class for areas with high-pressure, hot-water washdown |
The IP69K test was first defined for road vehicles in DIN 40050-9 and is now part of ISO 20653; IEC 60529 also includes a similar IPX9 test. The test itself is this: water at about 80 °C and 80–100 bar is sprayed from 10–15 cm at a sample on a turntable from angles of 0°, 30°, 60° and 90°. The tests of the classes don’t include each other. That’s why IP66/IP67 and IP69K are usually required together for a camera in a washdown zone. For the general framework of the codes, see IEC’s explanation of IP ratings; IP/IK selection outdoors is the subject of the IP and IK ratings for outdoor cameras article.
Housing material and chemical resistance
In washdown, water isn’t the camera’s only enemy. Alkaline foaming detergent, acidic descaler and chlorine-based disinfectant chemically wear the housing, gasket and dome every day. Material selection starts with the chemical list in the facility’s cleaning plan; this list is sent to the manufacturer and a compatibility statement is requested. No order is placed before the statement arrives.
- Stainless steel: The preferred housing in washdown zones is AISI 316L. Thanks to its molybdenum content, it resists chloride-induced pitting corrosion better than 304. An electropolished smooth surface reduces both corrosion and bacterial adhesion.
- Painted aluminum: Suitable for offices and dry storage. In a washdown zone, if the paint scratches or blisters, the aluminum underneath corrodes, and flaking paint becomes a foreign matter risk.
- Gaskets: The suitability of gasket materials such as silicone, EPDM and FKM for the chemicals used and the washdown temperature is asked separately. A gasket that hardens or swells quietly lowers the IP rating. The failure shows up months later as a drop inside the dome.
Glass or polycarbonate?
Food safety management systems treat glass and brittle hard plastics as registered materials with a breakage procedure. If a camera with a glass window breaks in an exposed product area, the line stops and product may be destroyed. That’s why polycarbonate domes or windows come to the fore in exposed product areas. Polycarbonate has its limit too: some strong alkaline and solvent-based cleaners cloud or crack the surface, and abrasive cloths scratch it. Whichever is chosen, the camera goes into the facility’s glass and brittle materials register and is included in periodic integrity checks.
Selection table by hygiene zone
Zone names and boundaries aren’t the camera installer’s job; they belong to the facility’s HACCP plan and food safety team. The table below is a starting point for a typical zoning; match it to your own facility’s map:
| Zone | Medium | Housing and protection | Dome/window |
|---|---|---|---|
| Dry storage, dispatch | Dust, forklifts, dry cleaning | Standard industrial, IP66, IK10 | Standard |
| Packaged product, post-packaging | Limited wet cleaning | IP66/IP67, housing with durable paint | Polycarbonate |
| Preparation and processing (wet) | Daily foam washdown, humidity | 316L stainless, IP69K | Polycarbonate, chemical compatibility confirmed |
| High hygiene / exposed product | Intensive washdown, disinfectant, hot water | 316L hygienic design, IP69K, no external screws or horizontal surfaces | Polycarbonate; glass only with a risk assessment |
| Cold rooms and blast chilling | Sub-zero temperatures, condensation when doors open | Heated housing, low-temperature rating | Anti-fog |
The cold room row is a subject in itself; details are in the cold storage cameras article.
Hygienic design, mounting and cable entries
The principle of hygienic design is simple: leave no surface, gap or pocket where water and dirt can cling during cleaning. In machine design, these principles are described by ISO 14159 and the EHEDG guidelines. Applied to a camera, things go wrong in the mounting more than in the housing. Common mistakes are the opposite of the items below:
- External surface: A sloped housing instead of a flat top surface; no exposed screw heads, labels or adhesives outside. The dome–housing joint is sealed with a one-piece gasket.
- Mounting bracket: The camera isn’t pressed directly against the wall or ceiling; it’s mounted with a stand-off so its back can be washed too. Hollow tube bracket arms collect water inside; choose a closed bracket with drainage considered.
- Position: The camera isn’t placed directly above exposed product, a conveyor or a filling nozzle. A falling part or a drop of condensation must not reach the product.
- Cable entry: A factory-fitted IP69K-rated M12 connection or the stainless cable gland defined in the certification. Before the entry, the cable makes a downward “drip loop”; water running down the cable drips to the floor instead of reaching the gland.
- Cable route: In exposed product areas, cable trays don’t run above the product line. Instead of a tray, washable stainless conduit or individual cables standing off the wall are preferred; the chemical resistance of the sheath is also checked.
- Junction boxes and switches: Not inside the wet zone, but in a technical corridor or cabinet outside the hygiene zone. Moving a PoE switch into the wet area is a risk of both failure and contamination.
Don’t say “we’ll deal with it later” for the mounting bracket. The wrong bracket kills the right camera in a washdown zone within a few months.
Image requirements for quality and traceability
A quality camera answers a different question from a security camera: “How was this batch packed, on this line, at this time?” Answering this question depends on three conditions.
- The right level of detail: A general line view shows the process flow; if labels, date codes or seals are to be checked, a separate, narrow-angle camera is needed at that point. That the characters to be read cover enough pixels on screen is verified with a test recording after installation. A calculation on paper isn’t enough.
- Time synchronization: The clocks of the cameras and recording system are connected to the same NTP source as the line PLC and MES. In a system whose clocks drift by a few minutes, searching for complaint footage turns into guesswork.
- Event matching: If events such as batch start and end, recipe changes and line stoppages are written to the VMS as markers, there’s no need to watch hours of recordings. The connection is usually made through the VMS’s API or generic event inputs; for options, see the camera API, ERP and MES integrations page.
The retention period of quality recordings is linked to the product’s shelf life and the complaint process, and can be set differently from security recordings. Production cameras also record employees; purpose, duration and access rules must be defined from the perspective of personal data legislation. The employee monitoring with cameras in the workplace article provides a framework.
Fogging, steam and temperature changes
Most fault calls from food facilities aren’t about broken cameras but about fogged images. Cooking, blanching and hot water washdown raise ambient humidity quickly; if the dome surface is below the ambient dew point, a film of water forms on it. The camera is working. But it isn’t seeing.
| Symptom | Likely cause | Fix |
|---|---|---|
| Blurred image for 20–30 minutes after washdown | External condensation on the cold dome surface | Dome heater, anti-fog coating, a position away from ventilation airflow |
| Droplets inside the dome | Humid air has entered the housing; the gasket is worn | Gasket replacement, desiccant pack, pressure equalization membrane (if present) |
| White veil at night or in low light | IR light reflecting off steam and stainless surfaces | Switching IR off and using ambient lighting; positioning the camera so it doesn’t face reflective surfaces head-on |
| Permanent clouding of the dome | Chemical incompatibility or abrasive wiping | A chemically compatible dome; adding a camera wiping method to the cleaning instructions |
The first thing to check to isolate the fault is whether the dome is fogged inside or outside. Fog outside is a position and heater problem; moisture inside is a gasket or sealing problem and doesn’t go away with wiping. Since production areas are lit throughout the shift, IR isn’t needed at most points; switching it off ends reflections from steam and stainless surfaces in one move.
Installation and maintenance checklist
- The chemical list and washdown temperature/pressure from the cleaning plan were sent to the manufacturer and a compatibility statement was received.
- The hygiene zone, housing material and IP rating of each camera were entered in the table; the selection matches the zone.
- The IP69K certification was verified together with the cable entry and mounting bracket used.
- Cameras in exposed product areas were added to the glass and brittle materials register.
- Cameras aren’t above the product line; their backs are at a washable distance.
- Switches, junction boxes and UPSs are outside the hygiene zone.
- The NTP source is shared with line systems; the time difference was measured in the acceptance test.
- At the first washdown after installation, image quality, fogging time and sealing were observed on site.
- Gasket, dome and gland checks were added to periodic maintenance; the camera maintenance checklist can be used as a basis for the general steps.
Make the first real washdown part of the acceptance test. A camera approved at the desk is tested in the first foam-and-rinse cycle. In a facility with hygiene zones, selection starts with a survey carried out with the quality and production teams; for general production area design, see our factory and production facility camera systems page.
Frequently asked questions
Is an IP67 camera enough in a food production area?
It may be enough in areas cleaned only by hose rinsing or dry cleaning. In zones with high-pressure, hot-water washdown, IP69K is required; IP67 tests immersion, not a pressure jet.
Can 304 stainless steel be used for the camera housing?
It can be used in dry or lightly wet areas. In washdown zones where chlorine-based disinfectant is used regularly, 316L, which is more resistant to pitting corrosion, is preferred.
Is a separate camera needed for quality tracking?
Yes, if small details such as labels, date codes or seals have to be read. A general line camera shows the process flow but doesn’t capture these details at readable resolution; a separate narrow-angle camera aimed at the relevant point is needed.
Why does the image blur after washdown?
Usually it’s humid air condensing on the cold dome surface. A dome heater, an anti-fog coating and a position away from ventilation airflow largely solve the problem. If the moisture is inside the dome, the problem is the gasket or sealing.