Ex-Proof Camera Selection and Installation Principles for ATEX Zones

ATEX camera selection: Zone 0/1/2 and 20/21/22, reading the Ex label, Ex d and Ex t protection types, gas group, temperature class, gland and earthing mistakes.
Technical summary
Technology
ATEX 2014/34/EU, 1999/92/EC, IEC 60079-0, IEC 60079-1, IEC 60079-14, IEC 60079-17, IEC 60079-28, IECEx
Topic
Selecting, installing and maintaining cameras in explosive atmospheres
Level
Intermediate–advanced
Prerequisites
  • The facility’s explosion protection document and zone map
  • General familiarity with IP camera and PoE infrastructure
In this article9 sections

In an explosive atmosphere, a wrongly chosen camera becomes the very risk it should be monitoring: an ignition source. Refineries, paint lines, solvent stores, flour and sugar silos, biogas plants, fuel stations; in all of them, camera selection differs fundamentally from ordinary outdoor selection. Below is how to read the Ex label, what the protection types mean and the points that commonly go wrong in installation and maintenance. Zone classification isn’t done here; that job belongs to the facility’s explosion protection document prepared by competent persons.

Explosive atmosphere zones and who defines them

In the EU, two ATEX directives work together: 2014/34/EU regulates the manufacture and conformity assessment of equipment, and 1999/92/EC the management of risk in the workplace. Their Turkish counterparts are the regulation on equipment used in potentially explosive atmospheres and the Regulation on the Protection of Employees from the Hazards of Explosive Atmospheres. The latter requires the employer to have an explosion protection document dividing areas into zones. No zone map, no camera project.

Zones are defined by how often and how long an explosive atmosphere is present. The IEC 60079-10-1 method is used for gas/vapor and IEC 60079-10-2 for dust.

Gas/vapor Dust Explosive atmosphere ATEX equipment category EPL
Zone 0 Zone 20 Continuous, for long periods or frequent Category 1 Ga / Da
Zone 1 Zone 21 Likely to occur occasionally in normal operation Category 2 (or 1) Gb / Db
Zone 2 Zone 22 Not expected in normal operation; if it occurs, short-lived Category 3 (or 1, 2) Gc / Dc

The areas we encounter in camera work are mostly Zone 1/2 and Zone 21/22. Zone 0 is usually a volume such as a tank interior where a camera isn’t placed anyway. If such a need arises, moving the camera outside the zone and viewing through a window or another method is often the better engineering.

Reading the Ex label

An Ex camera’s label carries two separate markings: the ATEX marking and the Ex marking based on IEC 60079-0. At the quotation stage, people often look only for the word “ATEX” and move on; that’s where problems on site come from. A typical label of an ex-proof camera certified for gas and dust looks like this:

CE xxxx  (Ex)  II 2G  Ex db IIC T6 Gb
               II 2D  Ex tb IIIC T85°C Db
-40 °C ≤ Ta ≤ +60 °C      IP66/IP68
Certificate: XXXX 24 ATEX 0000 X    IECEx XXX 24.0000X
Field Meaning
CE xxxx Conformity mark and the number of the notified body supervising production
(Ex) II Explosion protection mark; equipment group II (non-mining)
2G / 2D Category 2, gas (G) or dust (D) atmosphere
Ex db / Ex tb Protection type and level: flameproof enclosure / dust protection by enclosure
IIC / IIIC Gas group / dust group
T6 / T85°C Temperature class / maximum surface temperature
Gb / Db Equipment protection level (EPL)
Ta range Ambient temperature for which the certificate is valid; if not marked, −20 °C to +40 °C is assumed
X / U suffix X: specific conditions of use apply; U: Ex component certificate that can’t be used on its own

The X at the end of the certificate number is the detail installers most often skip. If the specific conditions in the certificate (such as a particular gland type, an electrostatic charging warning or a mounting orientation) aren’t applied, the camera isn’t considered properly installed even if its label is correct. Don’t go out to install without reading the X conditions. A camera’s IECEx certificate can be verified in the certificate database on the official IECEx website.

Comparison of protection types

Most Ex cameras are built on a flameproof stainless housing (Ex d); the connection compartment may use a different protection type. The main protection types found in enterprise camera systems:

Protection type Standard Principle Use in cameras
Ex d (db/dc) IEC 60079-1 Contains an internal explosion within the enclosure; no flame passes out through the flame path The most common camera housing
Ex e (eb/ec) IEC 60079-7 Structurally prevents arcs, sparks and excessive temperatures Terminals/junction box
Ex i (ia/ib/ic) IEC 60079-11 Limits the energy in the circuit to a level unable to cause ignition Special low-power designs; rare in practice with PoE
Ex p IEC 60079-2 Pressurizes the enclosure with protective gas Large enclosures, special applications
Ex t (ta/tb/tc) IEC 60079-31 Prevents dust ingress into the enclosure and limits surface temperature Dust zones
Ex op IEC 60079-28 Limits the ignition risk of optical radiation (IR, laser, fiber) IR illuminators, lasers, fiber links

If a camera with an IR illuminator or a fiber link is being considered, ask whether optical radiation risk is addressed in the certificate. An Ex d housing doesn’t cover the risk of optical emission. It’s a separate question.

Gas group and temperature class

The gas group is determined by how easily the gas in the atmosphere ignites. Requirements get stricter from IIA to IIC; a camera marked IIC can also be used in IIB and IIA atmospheres, but not the other way round. A product marked “IIB + H2” is suitable for IIB gases and hydrogen but not for acetylene, which is in group IIC. If this detail is missed in a workshop using acetylene, the label is “almost right.” Almost right is wrong.

Group Representative substance Note
IIA Propane Least demanding gas group
IIB Ethylene Covers IIA
IIC Hydrogen, acetylene Covers all gas groups
IIIA / IIIB / IIIC Combustible flyings / non-conductive dust / conductive dust IIIC covers IIIB and IIIA

The temperature class is the highest temperature any surface of the equipment can reach, and it must stay below the ignition temperature of the gas present: T1 450 °C, T2 300 °C, T3 200 °C, T4 135 °C, T5 100 °C, T6 85 °C. A T6 camera can also be used in atmospheres requiring T1–T5. This value is valid only within the Ta range on the label. For a pole camera heated by the sun, the upper Ta limit is checked separately; on a summer afternoon, a metal housing gets noticeably hotter than the ambient air.

For dust atmospheres, the marking is given directly as a temperature (such as T85°C). Under IEC 60079-14, the surface temperature must not exceed two thirds of the minimum ignition temperature of the dust cloud, and for a dust layer up to 5 mm it must be 75 K below the layer ignition temperature. Thick dust deposits need a separate assessment. That’s why the cleaning plan is part of the design, not a detail the operator sorts out later.

Cable entry, network connection and earthing

A significant share of field failures and inspection findings on Ex cameras come not from the camera itself but from the cable entry. The first place to look during an inspection is the gland.

  • Gland: Only Ex d certified cable glands are fitted to an Ex d housing. Depending on cable type and application, the IEC 60079-14 selection rules may require a barrier (compound-filled) gland. The gland’s thread type (such as M20×1.5 or NPT) must match the housing exactly; a mismatched thread isn’t “made to fit” with an adapter.
  • Unused entries: Closed with a certified Ex stopping plug. A dust plug or shipping cap isn’t a permanent solution; we often see them still in place on site years later.
  • Network cable: Ethernet and PoE circuits aren’t intrinsically safe. The cable is laid with a type and route compliant with IEC 60079-14, usually armored cable. The switch, NVR and PoE injector sit in a cabinet in the safe area, outside the hazardous area. If fiber is preferred over long distances, an Ex op assessment is needed for optical power.
  • Earthing and equipotential bonding: The camera’s external earth terminal is connected to the facility’s equipotential bonding system; how the armor and screen are earthed is set according to the facility’s earthing design. General principles on the network infrastructure side are explained in the telecommunications grounding and bonding article.
  • Lightning and overvoltage: On poles in open areas, surge protection is part of the design; the placement of protective devices must also follow the zone classification. For the general approach, see the lightning and surge protection for camera systems article.

Maintenance and modification restrictions

An Ex camera must keep meeting the conditions of its certificate after installation too. IEC 60079-17 defines inspections at different grades: visual, close and detailed; the initial inspection is done before commissioning, and periodic inspections at intervals set by the facility. Points we watch on site specifically for cameras:

  • The housing isn’t opened while energized when an explosive atmosphere may be present. If it has to be opened, the workplace’s permit-to-work procedure (gas testing, hot work permit and so on) is applied.
  • Flameproof joints (flame paths) aren’t scratched or painted, and no gasket or sealant not in the certificate is placed between them. All cover bolts are fitted, and of the specified grade. A single missing bolt invalidates the protection type.
  • No extra holes are drilled in the housing, and the window isn’t replaced with anything other than an original part. A plastic sunshield, label or coating not included in the certificate can create an electrostatic charging risk.
  • In dust zones, dust accumulating on the housing is cleaned before it reaches a thickness that would upset the temperature class calculation.
  • Repairs are carried out under IEC 60079-19 by the manufacturer or a competent service. Firmware updates are normally done over the network and don’t require opening the housing; the rules above apply to any intervention that requires opening the housing on site. If an update changes IR power or illuminator behavior, have the manufacturer confirm it against the Ex op conditions.

Camera-specific design questions

An Ex camera is expensive, heavy and laborious to maintain. That’s why the first question shouldn’t be “which Ex camera” but “is an Ex camera really needed here.” In many facilities, the hazardous area can be viewed with a suitable lens from a safe point outside the zone boundary. Then a standard industrial camera is enough, and the inspection burden disappears. The cheapest Ex camera is the one you don’t install. If a thermal camera is being considered for leak or overheating monitoring, the limits of this use are explained in the thermal camera applications article. General design of production areas outside the hazardous area is the subject of the factory camera system design guide.

Selection checklist

  • The zone map from the explosion protection document has been obtained; the zone of each camera point (0/1/2, 20/21/22) is known.
  • The facility has stated the groups and ignition temperatures of the gases and dusts that may be present in the zone.
  • Camera category/EPL, gas group, temperature class and Ta range are suitable for each point.
  • The ATEX declaration of conformity and certificate have been obtained; the X conditions have been read and entered in the installation instructions.
  • If there’s an IR illuminator or fiber, optical radiation risk is addressed in the certificate.
  • Glands, plugs and cable type comply with the certificate and IEC 60079-14; thread types match.
  • Switches, NVRs and injectors are in the safe area; earthing and equipotential bonding have been designed.
  • Water and mechanical resistance were checked separately; Ex certification doesn’t replace the IP rating. For details, see IP and IK ratings for outdoor cameras.
  • The initial inspection record, Ex equipment inventory and periodic inspection plan have been created.

In production and energy facilities with explosive atmospheres, we carry out camera design together with the facility’s Ex team. For related services, see the factory and production facility camera systems and critical infrastructure and wide-area perimeter surveillance pages.

Frequently asked questions

Can a Zone 1 certified camera be used in Zone 2?

Yes. Category 2 (EPL Gb) equipment can be used in Zone 1 and Zone 2. The reverse isn’t true: Category 3 equipment can’t be installed in Zone 1.

Can an IP68 camera be used in an explosive atmosphere?

No. The IP rating defines protection against water and dust ingress, not ignition risk. An explosive atmosphere needs ATEX or IECEx certified equipment marked for the zone.

Can the camera company do the zone classification?

Zone classification is the employer’s responsibility and is carried out by competent persons who know the IEC 60079-10-1 (gas) and IEC 60079-10-2 (dust) methods. Camera design uses this classification as an input; it doesn’t replace it.

Can an Ex camera be powered by PoE?

Some Ex cameras can be powered by PoE. In that case, the PoE switch or injector must be outside the hazardous area, the cable type and route must be chosen in line with IEC 60079-14, and the conditions of use in the certificate must be followed.